Concept
Availability Zones
Isolated locations inside a Region, each one or more data centers. Using two or more keeps an application running.
Own power
Separate utility power and backup generators for each AZ.
Own cooling
Cooling equipment is not shared between AZs.
Own network
Each AZ has its own redundant links to the internet.
Kilometers apart
Far enough apart that one flood, fire or earthquake should not hit two AZs.
Updated at different times
AWS spreads service updates over time, so a bad change does not reach every AZ at once.
Fast private links
Encrypted, low-latency fiber joins the AZs, so data can be copied between them as it is written.
1 / 2
Own power
Separate utility power and backup generators for each AZ.
Own cooling
Cooling equipment is not shared between AZs.
Own network
Each AZ has its own redundant links to the internet.
Kilometers apart
Far enough apart that one flood, fire or earthquake should not hit two AZs.
2 / 2
Updated at different times
AWS spreads service updates over time, so a bad change does not reach every AZ at once.
Fast private links
Encrypted, low-latency fiber joins the AZs, so data can be copied between them as it is written.
What it is
An Availability Zone (AZ) is one or more data centers inside a Region, with redundant power, networking and connectivity. Its name is the Region code plus a letter, such as eu-west-1a.
The AZs in a Region do not share single points of failure. Each has its own power supply and backup generators, its own cooling and its own network links. They are many kilometers apart, so a flood, fire or earthquake that hits one should not hit another. AWS also rolls out updates to the AZs of a Region at different times.
What it is
Yet the AZs are close enough, within about 100 km of each other, to be joined by fast, private fiber. Data can be copied between them as it is written. This is what makes high availability practical: run in two or more AZs, and the loss of one does not stop you.
Remember
- An AZ is one or more data centers. A Region has at least three AZs.
- No shared power, cooling or network, so one AZ can fail while the others keep running.
- Many kilometers apart, but within about 100 km (60 miles) of each other.
- Traffic between AZs travels over encrypted, low-latency fiber.
Remember
- Some resources sit in one AZ only, such as an EC2 instance or an EBS volume.
On the exam
- “One or more discrete data centers with redundant power, networking and connectivity” is the definition of an Availability Zone.
- “Availability Zones are physically separate and do not share single points of failure” is a true statement. It is why several AZs give high availability.